_Ref_ |
Id |
_________Element Name__________ |
Req |
Type |
Min/Max |
___Usage___ |
  |
  |
PAM01 |
673 |
Quantity Qualifier |
C |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code specifying the type of quantity |
  |
  |
  |
All valid standard codes are used. |
  |
PAM02 |
380 |
Quantity |
C |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Numeric value of quantity |
  |
PAM03 |
C001 |
Composite Unit of Measure |
C |
Comp |
  |
Used |
  |
  |
  |
  |
Description: To identify a composite unit of measure(See Figures Appendix for examples of use) |
  |
  |
355 |
Unit or Basis for Measurement Code |
M |
ID |
2/2 |
Must use |
  |
  |
  |
  |
Description: Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken |
  |
  |
  |
All valid standard codes are used. |
  |
  |
1018 |
Exponent |
O |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Power to which a unit is raised |
  |
  |
649 |
Multiplier |
O |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Value to be used as a multiplier to obtain a new value |
  |
  |
355 |
Unit or Basis for Measurement Code |
O |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken |
  |
  |
  |
All valid standard codes are used. |
  |
  |
1018 |
Exponent |
O |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Power to which a unit is raised |
  |
  |
649 |
Multiplier |
O |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Value to be used as a multiplier to obtain a new value |
  |
  |
355 |
Unit or Basis for Measurement Code |
O |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken |
  |
  |
  |
All valid standard codes are used. |
  |
  |
1018 |
Exponent |
O |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Power to which a unit is raised |
  |
  |
649 |
Multiplier |
O |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Value to be used as a multiplier to obtain a new value |
  |
  |
355 |
Unit or Basis for Measurement Code |
O |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken |
  |
  |
  |
All valid standard codes are used. |
  |
  |
1018 |
Exponent |
O |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Power to which a unit is raised |
  |
  |
649 |
Multiplier |
O |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Value to be used as a multiplier to obtain a new value |
  |
  |
355 |
Unit or Basis for Measurement Code |
O |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken |
  |
  |
  |
All valid standard codes are used. |
  |
  |
1018 |
Exponent |
O |
R |
1/15 |
Used |
  |
  |
  |
  |
Description: Power to which a unit is raised |
  |
  |
649 |
Multiplier |
O |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Value to be used as a multiplier to obtain a new value |
  |
PAM04 |
522 |
Amount Qualifier Code |
C |
ID |
1/3 |
Used |
  |
  |
  |
  |
Description: Code to qualify amount |
  |
  |
  |
All valid standard codes are used. |
  |
PAM05 |
782 |
Monetary Amount |
C |
R |
1/18 |
Used |
  |
  |
  |
  |
Description: Monetary amount |
  |
PAM06 |
344 |
Unit of Time Period or Interval |
C |
ID |
2/2 |
Used |
  |
  |
  |
  |
Description: Code indicating the time period or interval |
  |
  |
  |
All valid standard codes are used. |
  |
PAM07 |
374 |
Date/Time Qualifier |
C |
ID |
3/3 |
Used |
  |
  |
  |
  |
Description: Code specifying type of date or time, or both date and time |
  |
  |
  |
All valid standard codes are used. |
  |
PAM08 |
373 |
Date |
C |
DT |
8/8 |
Used |
  |
  |
  |
  |
Description: Date expressed as CCYYMMDD |
  |
PAM09 |
337 |
Time |
C |
TM |
4/8 |
Used |
  |
  |
  |
  |
Description: Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99) |
  |
PAM10 |
374 |
Date/Time Qualifier |
C |
ID |
3/3 |
Used |
  |
  |
  |
  |
Description: Code specifying type of date or time, or both date and time |
  |
  |
  |
All valid standard codes are used. |
  |
PAM11 |
373 |
Date |
C |
DT |
8/8 |
Used |
  |
  |
  |
  |
Description: Date expressed as CCYYMMDD |
  |
PAM12 |
337 |
Time |
C |
TM |
4/8 |
Used |
  |
  |
  |
  |
Description: Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99) |
  |
PAM13 |
1004 |
Percent Qualifier |
C |
ID |
1/2 |
Used |
  |
  |
  |
  |
Description: Code to qualify percent |
  |
  |
  |
All valid standard codes are used. |
  |
PAM14 |
954 |
Percent |
C |
R |
1/10 |
Used |
  |
  |
  |
  |
Description: Percentage expressed as a decimal |
  |
PAM15 |
1073 |
Yes/No Condition or Response Code |
O |
ID |
1/1 |
Used |
  |
  |
  |
  |
Description: Code indicating a Yes or No condition or response |
  |
  |
  |
All valid standard codes are used. |